World Rural Health Conference
Home Print this page Email this page Small font size Default font size Increase font size
Users Online: 3514
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 8  |  Issue : 2  |  Page : 401-406

An investigation into the clinical accuracy of twinkling artifacts in patients with urolithiasis smaller than 5 mm in comparison with computed tomography scanning


Department of Radiology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Correspondence Address:
Dr. Mohammad Qasem Hanafi
Department of Radiology, Ahvaz Jundishapur University of Medical Sciences, Ahvaz
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jfmpc.jfmpc_300_18

Rights and Permissions

Background: Ultrasound (US) is a non-invasive method used for the diagnosis of urolithiasis. If the size of the stone is <5 mm, it may be difficult to diagnose. This study aimed to compare the accuracy of twinkling artifact (TA) of color Doppler US imaging with unenhanced computed tomography (CT) for detecting urolithiasis <5 mm. Materials and Methods: This prospective study was conducted on 100 patients with suspected renal calculus presented to the emergency room at the Imam Khomeini Hospital of Ahwaz in 2018. The US findings such as posterior acoustic shadowing and TA were examined for their ability to detect urinary stones (greatest diameter ≤5 mm) using CT findings as the gold standard. Results: The mean size of renal stone was 3.43 ± 0.80 mm in CT and 3.49 ± 0.82 mm in color Doppler US. There was no significant difference between CT and color Doppler US report in quantification of urolithiasis sizes (P = 0.603). TA on color Doppler US was detected in 94 (94%) patients while posterior acoustic shadow was detected in 83 (83%) patients (P = 0.004). A significant difference was found between the TA and size of stones (P = 0.036). The sensitivity, accuracy, and positive predictive values of TA for the detection of calculus were 94%, 94%, and 100%, respectively. Conclusion: The results demonstrated that TA on color Doppler US could be a good and safe alternative imaging modality with comparable results with non-contrast-enhanced computed tomography for the sensitive detection of urolithiasis <5 mm.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed542    
    Printed5    
    Emailed0    
    PDF Downloaded89    
    Comments [Add]    

Recommend this journal