Heparin flush vs. normal saline flush to maintain the patency of central venous catheter among adult patients: A systematic review and meta-analysis


1 Professor Cum Principal, Center of Excellence in Nursing Education and Research, AIIMS, Rishikesh, Uttarakhand, India
2 Nursing Tutor, Center of Excellence in Nursing Education and Research, AIIMS, Rishikesh, Uttarakhand, India
3 Assist. Professor, Center of Excellence in Nursing Education and Research, AIIMS, Rishikesh, Uttarakhand, India
4 PhD Scholar, College of Nursing, Center of Excellence in Nursing Education and Research, AIIMS, Rishikesh, Uttarakhand, India

Date of Submission22-Aug-2019
Date of Decision22-Aug-2019
Date of Acceptance09-Sep-2019
Date of Web Publication30-Sep-2019

Correspondence Address:
Dr. Shiv K Mudgal
Nursing Tutor Center of Excellence in Nursing Education and Research, AIIMS, Rishikesh, Uttarakhand
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jfmpc.jfmpc_669_19

Rights and Permissions
  Abstract 


Background: Around the globe, protocols for flushing the catheter to maintain the patency of central venous catheter (CVC) vary by institution to institution or by practitioner to practitioner. Therefore, this review was carried out with the aim of evaluating the efficacy of heparin flush vs. normal saline flush to maintain the patency of CVC among adult patients. Methods: We followed the guidelines of Cochrane handbook for interventions and searched in MEDLINE, Embase, Cochrane library, Clinical trials database, and reference list of related articles, which were published from Jan. 2012 to 31 Dec. 2018 in English language. We included only randomized controlled trials, and nine studies were included in this review. The pooled standard mean difference and relative risk were calculated by using Rev Man Review Manager 5. Results: We identified nine eligible studies with a total number of 3,113 participants. Consolidated results from eight studies conveyed little favorable effect to maintain patency of CVC with heparin when compared with normal saline as evident by risk ratio 0.83, 95% CI 0.50 – 1.40; P = 0.13. We also carried out analysis for secondary outcomes, and there was no evidence that heparin was better than normal saline in terms of safety except heparin-induced thrombocytopenia. Conclusions: Heparin has little favorable effects to maintain patency of catheter than normal saline but not in secondary outcomes. As the quality of evidence was very low, therefore, results should be comprehend with care.

Keywords: Central venous catheter, heparin, normal saline, patency


How to cite this article:
Sharma SK, Mudgal SK, Gaur R, Sharma R, Sharma M, Thakur K. Heparin flush vs. normal saline flush to maintain the patency of central venous catheter among adult patients: A systematic review and meta-analysis. J Family Med Prim Care 2019;8:2779-92

How to cite this URL:
Sharma SK, Mudgal SK, Gaur R, Sharma R, Sharma M, Thakur K. Heparin flush vs. normal saline flush to maintain the patency of central venous catheter among adult patients: A systematic review and meta-analysis. J Family Med Prim Care [serial online] 2019 [cited 2019 Dec 15];8:2779-92. Available from: http://www.jfmpc.com/text.asp?2019/8/9/2779/268070




  Introduction Top


Central venous catheters (CVCs) are routinely utilized in health care industries, primarily in critically care units.[1] CVC is a device that is temporarily placed into patients for assessing the central veins. It is also known as lines.[2],[3] CVCs can be used for monitoring hemodynamic status, administration of parental nutrition, blood and blood products,[2],[3] medications or chemotherapy drugs, and performing of hemodialysise ct. when it is not safe to administer through peripheral venous catheters.[4],[5]

Presently, four types of CVCs commonly used are tunneled (e.g. Hickman's Catheters), non-tunneled catheter, peripherally inserted central catheters (PICCs), and totally implantable port or totally implantable venous access devices.[5],[6]

CVCs are having great use in critical care units and associated with decrease stay of hospitalizations, enhance the patient's safety, and reduction of the hospitalization costs.[7],[8] However, CVCs are associated with complications. Complications related to CVCs can be mechanical complications, which occur at the time of insertion such as hematoma, arterial puncture; pneumothorax, etc., ranges from 5% to 29%[9],[10] and complications related to infections ranges from 5% to 26% and complications related to thrombosis ranges from 2% to 26%.[10],[11]

CVCs obstruction may lead to venous thrombosis or develop a fibrin sheath, accounts approximately 40% of catheter-related complications, which are major causes for catheter dysfunctions.[12] Occlusion of catheter can be categorized as partial (able to flush freely but not able to aspirate the blood) and complete (not able to flush freely and aspirate blood).[13],[14]

There are various factors like condition of patient, lumen size and position of catheter, insertion site and technique, chemical composition and nature of flushing solution, etc., which are associated with catheter-related thrombosis.[15] Catheter-related thrombosis is an important causative factor for not only morbidity and mortality but also that thrombus acts as a medium for micro-organism growth.[16] Another complication which is associated with CVC-related upper limb DVT is pulmonary embolism, which is a life-threatening situation, occurs near about 15% of patients.[17]

Therefore, to prevent the risk of catheter occlusion, it is very much needed for maintaining patency and prolong functioning of the catheter,[18],[19] and to achieve it proper flushing of catheter is deemed necessary and considered as primary intervention.[20],[21] To prevent or avoid formation of thrombus in CVCs, the solutions used by clinician to flush the catheter include heparin, 0.9% sodium chloride, vitamin C, lepirudin, sodium citrate, polygelin,[22],[23] alteplase, or urokinase.[24]

Heparin flushing has been used and most commonly performed procedure to avoid thrombus formation in CVCs.[25] Heparin flush is the standard guideline to maintain the patency of CVCs.[26],[27],[28] However, the effectiveness of this standard practice is still unproven [29] and associated with some complications such as heparin-induced thrombocytopenia (HIT), allergy, and risk of bleeding.[30],[31],[32]

It is reported by some studies that utilization of normal saline is as much effective as heparin to maintain the patency of CVC.[33],[34],[35] Furthermore, two Cochrane systematic reviews provided inconclusive evidence favoring the application of heparin solution over normal saline for maintaining the patency of central venous and arterial catheters.[36],[37]

As such, a number of studies with conflicting results have been published, prompting further debate on which solution is better for CVC maintenance. Therefore, this systematic review and metaanalysis of RCTs was carried out to assess more precisely the effectiveness of heparin in maintaining CVCs when compared with normal saline.


  Materials and Methods Top


We followed PRISMA guidelines for this systematic review and meta-analysis [Additional file 1]. The PICO framework was utilized to address the review question evidently [Additional file 2]. The primary outcome for this review was catheter patency, and secondary outcomes were catheter-related infection, venous thrombosis, HIT, bleeding, and mortality.



Study selection

There were two independent reviewers who read the title and abstract and wherever needed the full text of applicable or probably related references, to select studies which required being more detail examination. When there was any variation of opinions between both reviewers, then first author was consulted to make final conclusion for the study. We also tried to contact the authors of ongoing trials and whose studies needed more clarification. In this review, we included randomized controlled trials (RCTs) compared the efficacy of heparin flush versus normal saline flush to maintain the patency of CVC in adult patients and published in English language only. Studies were excluded when primary researcher uses other methods of randomization like quasi randomization, studies on non-human, case-control, cohort studies, letters and reviews, and age of participants <18 years of age.

Search strategy

Review authors screened the Cochrane library l (last search 31 December 2018). We also searched MEDLINE (Ovid, 2012 to 2018), Embase (Ovid, 2012 to 2018), and clinical trials registers (last search 31 December 2018). We used free-text terms and MeSH terms like CVC, heparin, normal saline, sodium chloride, RCT, catheterization, flushing and patency, etc., [Additional file 3] for searching the studies. We explored all articles related to present review and also used list of references from searched published studies to identify new relevant studies.



Data extraction

There were two reviewers who extracted data and discussed with the third reviewer, who then solved the discrepancies. Data regarding the first author, publication year, country, study type, population, interventions (doses of heparin) outcomes (Primary and Secondary outcomes), and results were extracted. Whenever, it was required to get additional information, we approached the authors of those studies.

Assessment of bias

Risks of bias of studies were evaluated by two authors independently. Evaluation of risk bias was done by using standard guidelines of Cochrane. If there was any discrepancy between two authors, then the third reviewer was consulted to get the final judgment. Risk of bias comprised of random sequence generation, allocation concealment, blinding, incomplete outcome data, selective reporting it was assessed by using funnel plot [Figure 1], and other bias.
Figure 1: Funnel plot

Click here to view


Types of outcome

In the included studies, the primary outcomes of interest communicated were maintaining the patency and occlusion of CVC. Secondary outcomes were HIT, risk of bleeding or hemorrhage from any part in the body, infection and thrombosis related to CVC, allergic reaction to heparin, cost of treatment with heparin, and mortality.

Data analysis

Statistical analysis was done as per the statistical guidelines protocol in the current version of the Cochrane Handbook for Systematic Review of Randomized controlled trial. RevMan Manager 5 was used for review production and data analysis. Studies which assessed the effects of heparin flush to maintain the patency of CVC were analyzed for subgroups and secondary outcomes. There were three different types of unit for analysis: six studies (participants), two studies (catheters), and two studies (line access). In this present review, we utilized risk ratio (RR) for dichotomous data. The mean ± standard deviations (SD) were used to express the continuous data and analyzed using standard mean differences (SMDs). As I 2 values were low, which indicates heterogeneity is low. Hence, we are supposed to use fixed-effect model to pool data. However, we planned and used random-effect model (for continuous data) because although the same medication was used to flush or lock the CVC in all studies (heparin), we identified fairly heterogeneity in the study methods involved like different types of patients, distinct settings, dissimilar duration of follow-up, inconsistent amount of concentration of drug (heparin), etc. The fixed model (MantelHaenszel) was used for dichotomous data. The publication bias was assessed by using funnel plot.


  Results Top


Study selection and characteristics

We followed PRISMA guidelines for search and selection of studies, which met the inclusion criteria [Figure 2]. Total 1,157 records were searched through electronic database. Out of them, 762 were found as duplicates because of overlap of the database, remaining 395 references were screened and 357 records were found not relevant and excluded. Further,[38] full-text articles were assessed for eligibility and 29 of them were excluded because they did not meet the inclusion criteria. Finally, there are nine studies which met the pre-specified inclusion criteria and included for systematic review and meta-analysis.
Figure 2: Selection of studies as per PRISMA guideline [ICTRP = International Clinical Trials Registry Platform (WHO database)]

Click here to view


Baseline characteristics

In total, nine studies were included which originated from Belgium [39] (n = 1), Iran [40],[41],[42] (n = 3), India [43] (n = 1), Italy [44] (n = 1), and USA [45],[46],[47] (n = 3) and from those studies, only one study [44] was conducted at multi-centric level, remaining 8 studies were single centric. The concentration of heparin ranged from 10 IU/ml to 1000 IU/ml. The duration of follow-up varied from 1 day to 204 days and 1 day to 294 days in normal saline (NS) group and heparin group, respectively. There were only three studies [40],[41],[42],[43],[44],[45],[46] which carried out in non-ICUs setting, whereas remaining six were performed in critical care units, and all studies were reported from 2012 to 2018. The basic characteristics of included studies were presented in [Table 1].
Table 1: Basic characteristics of included studies

Click here to view


Methodological quality

Most of the studies expressed a low or unclear level of risk of bias, except in performance and detection bias as display in [Figure 3]. There were only two studies [43],[45] that did not clearly explain about method of randomization. In terms of allocation concealment, 4 trials [39],[44],[46],[47] discussed properly, whereas the remaining 5 trials were unclear about this. Furthermore, there were only two studies [41],[42] reported an appropriate method of blinding, one trial [46] was unclear and remaining all others have high risk for performance and detection bias. With regard to incomplete outcome data, only one study [39] had unclear risk, remaining others described drop-out information. In terms of selective reporting, only one study [43] had high risk of reporting bias, and three [40],[41],[47] were unclear risk and remaining low risk as they reported as per pre-specified protocols. There were five studies [40],[41],[42],[44],[46] which had a small sample size. The risk of bias was presented in [Figure 3]a and [Figure 3]b.
Figure 3: (a) Risks of bias graph. (b) Risks of bias summary

Click here to view


Meta-analysis

We identified nine eligible studies for present review and meta-analysis with a total number of 3,113 participants with different disease conditions. We identified variation in methods used by the included trials and difference in heparin strength (10 to 1000 IU/mL), duration of follow-up (1 to 294 days), participants with disease (participants with cancer or without cancer), and the unit of analysis which was used (participants, catheter, and catheter line access).

Consolidated results from eight studies (six studies used participants as unit of analysis with 1,622 participants and two studies used catheter as unit of analysis with 1,407 catheters) conveyed little favorable effect to maintain patency of CVC with heparin when compared with normal saline as evident by RR 0.83, 95% CI 0.50 to 1.40; P = 0.13.

We performed subgroup analysis on the basis of unit of analysis. When we used participants (1,622 participants from six studies) as unit of analysis, results reveal little favorable effect to maintain CVC patency with heparin than NS (RR 0.76, 95% CI 0.52 to 1.12; P = 0.16), whereas subgroup analysis was performed to use catheter as the unit of analysis exhibit no clear difference in maintaining patency of CVC between heparin and NS (RR 0.83, 95% CI 0.50 to 1.40; P = 0.49; 1407 catheters of two studies). When we used line access as unit of analysis, results reveal no clear difference in CVC patency between heparin and NS (RR 1.08, 95% CI 0.84 to 1.40; one study) [Figure 4].
Figure 4: Forest plot of comparison between normal saline (NS) vs. heparin flush and the patency of catheter

Click here to view


We also carried out subgroup analysis on the basis of kinds of participants, numbers of lumens, and strength of heparin concentration and duration of follow-up. We found no clear difference in catheter patency between participants without cancer and those with cancer (test for subgroup difference P = 0.72), and subgroup analysis to identify relationship between number of lumen (one lumen and two or more lumen) and catheter patency showed no clear difference between both group (test for subgroup difference P = 0.79). While subgroup analysis was performed between catheter patency and heparin strength (less or more than 1000 IU/ml) showed little difference. As less than 100IU/ml strength showed little favor to maintain patency (test for subgroup difference P = 0.47). Finally, we did analysis to detect the effect of follow-up duration and catheter patency and found that less than one-month follow-up had favorable effect when compared with the duration of follow-up was more than one-month (test for subgroup difference P = 0.23).

We studied to assess the difference of duration of CVC patency in three studies with 886 participants and 709 catheters and results reveal that there were no clear differences in duration of CVC patency between heparin and NS [Mean Difference (MD) 0.42 days, 95% CI –0.21 to 1.01; P = 0.16].

We also carried out analysis for secondary outcomes, and results show that except HIT, which was assessed in two studies with 395 participants showed there is no clear difference in the following outcomes: infection related to CVC in two studies with 1,097 participants (RR 0.74, 95% =0.03 to 19.54; P = 0.86), bleeding from any site in the body in three studies with 1,197 participants (RR 0.62, 95% =0.03 to 12.87; P = 0.76), CVC related thrombosis in three studies with 1,527 participants (RR 1.25, 95% =0.77 to 2.03; P = 0.37) and mortality in one study with 802 participants (RR 0.73, 95% =0.42 to 1.27; P = 0.26). Only one secondary outcome (HIT) in two studies with 395 participants show the contradictory effect with heparin (less cases of HIT in heparin group than NS group; RR 0.21, 95% =0.01 to 4.27; P = 0.31) [Figure 5].
Figure 5: Forest plot of comparison between normal saline (NS) vs. heparin flush and secondary outcomes

Click here to view


We downgraded the quality of evidence because of mainly unclear allocation concealment, imprecision, and doubt of publication bias.


  Discussion Top


CVC is used in clients with critical illness for the prevention of infection, injection of medications, and parenteral nutrition. Nurses along with other health care workers deal with such patients as a part of daycare routine, and if prevention of infection is done at an early stage, then it can reduce the risk of lung infection and other serious complication. Heparin and normal saline flush is used to keep the tubing patent until the administration of next medication and speedy recovery happens if used cautiously as primary prevention.

The use of CVC is common in critical care units for various purposes, but it is associated with some complications.[1],[2],[4] One of the major complications is catheter occlusion, and heparin is a widely used solution to prevent occlusion of catheter.[10],[11] However, complications such as allergic reaction, risk of bleeding, and HIT are associated with heparin flush.[25],[30],[31] While some studies provided evidence that NS is as effective as heparin for maintaining CVC patency and have some potential benefits like less complication and cost than heparin.[33],[34]

Therefore, the present review is carried out to identify which solution is better than other and results of our study revealed that heparin flush had a little favorable effect to maintain the patency of CVC when compared with NS, but there was no clear evidence of an effect on secondary outcomes between the groups.

There are few RCTs which compared heparin flush vs. normal saline flush for maintaining the patency of catheter in adults. One of the studies concluded that heparin was better than normal saline particularly in terms of catheter survival rate.[22] While some other studies showed that there is no difference in patency of catheter when heparin was compared with normal saline.[39],[40] Another report from a multicenter RCT [43] consisted with [39],[40] and concluded that heparin is not more effective than normal saline for maintaining CVCs patency, and there was no statistical difference was present.

Results of our review and meta-analysis are consistent with other reviews,[2],[3] explained that heparin was associated with fewer occlusion rate of CVC than NS, but quality of evidence was very low. They also concluded that there was no evidence of differences in secondary outcomes (infection, bleeding, thrombosis, HIT, and mortality).

The results of other reviews [36],[46] concluded that there is no evidence of a difference between the groups to maintain the patency of CVC. Another meta-analysis [47] revealed that there is no evidence of different effectiveness between heparin flushing and normal saline or other solutions in reducing catheter occlusion.

There are some systematic reviews that used heparin in CVCs but have different inclusion and/or exclusion criteria from this review as one review [48] was carried out among adults and pediatrics participants and concluded that there was a trend toward a decrease in catheter and venous thrombosis significantly when heparin is used. Another review [49] in adults participants with CVCs or PICCs and compared heparin locking, continuous heparin perfusion, NS locking, and urokinase locking versus any other protocol, concluded that there is clear evidence that heparin is more effective than NS. Furthermore, two similar systematic reviews [5],[50] carried out in pediatrics and concluded that it is still unclear whether heparin is required to maintain the patency of CVCs.

There are various factors like types of catheter, strength, amount, and frequency of heparin used for flushing, physical condition of patient, and puncture site that are associated with patency of CVC.[51],[52] Therefore, well-designed RCTs are required to identify the effect of these factors on the primary outcome.

We found some potential limitations in this review. First, although there was low statistically heterogeneity but methodological heterogeneity likes different kinds of participants, use different strength of heparin concentration, and duration of follow-up in included studies. Second, we explored MEDLINE, Embase, and Cochrane library but could not search CINHAL. In this review, most of the included studies were single centric and had a small sample size.


  Conclusion Top


As per the evidence of this review, there is little or no effect of heparin to maintain patency of catheter when compared with normal saline but no clear evidence between heparin and normal saline flush in secondary outcomes. Moreover, the quality of evidence was very low; therefore, we are not sure whether heparin flush is better to maintain CVC patency than NS flush and results should be comprehended with cautiously. Therefore, further, it is needed to carry out large scale RCTs with standard methodology and at a multi-centric level to produce clear evidence which solution is better in terms of maintaining the patency, cost-effectiveness, and safety of the patients.

Additional Files

Additional file 1: The PRISMA checklist.

Additional file 2: PICO framework.

Additional file 3: The search strategy and search results

Abbreviations

CI: confidence interval; CRBSI: catheter-related bloodstream infection; CVCs: central venous catheters; HIT: heparin-induced thrombocytopenia; ICUs: intensive care units; NS: normal saline; RCTs: randomized controlled; RR: relative risk.

Acknowledgment

We are very thankful to Ms. Anindita Mandal and Mr. Sandeep Singh for their contributions to the search and article preparation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.


  Medline search Top


International Clinical Trials Registry Platform

  • 125 records for 119 trials found for: Heparin AND Catheter
  • 7 records for 6 trials found for: Heparin AND cvc



  Embase search Top


  1. ('central venous catheter'/exp OR 'central venous catheter' OR (('central'/exp OR central) AND venous AND ('catheter'/exp OR catheter))) AND ('heparin'/exp OR heparin) AND ('normal saline'/exp OR 'normal saline' OR (normal AND ('saline'/exp OR saline))) 175
  2. ('central venous catheter'/exp OR 'central venous catheter' OR (('central'/exp OR central) AND venous AND ('catheter'/exp OR catheter))) AND ('heparin'/exp OR heparin) AND ('normal saline'/exp OR 'normal saline' OR (normal AND ('saline'/exp OR saline))) AND patency 49
  3. ('central venous catheter'/exp OR 'central venous catheter' OR (('central'/exp OR central) AND venous AND ('catheter'/exp OR catheter))) AND ('heparin'/exp OR heparin) AND ('normal saline'/exp OR 'normal saline' OR (normal AND ('saline'/exp OR saline))) AND patency AND ('adult'/exp OR adult) 189
  4. ('heparin'/exp OR heparin) AND ('0.9 % sodium chloride' OR (0.9 AND % AND ('sodium'/exp OR sodium) AND ('chloride'/exp OR chloride))) AND patency AND ('adult'/exp OR adult) 15
  5. ('heparin'/exp OR heparin) AND ('0.9 % sodium chloride' OR (0.9 AND % AND ('sodium'/exp OR sodium) AND ('chloride'/exp OR chloride))) AND ('occlusion'/exp OR occlusion) AND ('adult'/exp OR adult) 14
  6. ('heparin'/exp OR heparin) AND normal AND saline 944
  7. ('heparin'/exp OR heparin) AND normal AND saline AND central AND venous AND catheter 53
  8. ('central'/exp OR central) AND venous AND ('catheter'/exp OR catheter) AND ('heparin'/exp OR heparin) AND normal AND ('saline'/exp OR saline) AND patency 20
  9. ('central'/exp OR central) AND venous AND ('catheter'/exp OR catheter) AND ('heparin'/exp OR heparin) AND normal AND ('saline'/exp OR saline) AND patency AND adult 09




 
  References Top

1.
Contributor N. Choice and use of peripherally inserted central catheters by nurses [Internet]. Nursing Times 2019. Available from: https://www.nursingtimes.net/archive/choice-and-use-of-peripherally-inserted-central-catheters-by-nurses-01-05-2004/. [Last cited on 2019 Sep 11].  Back to cited text no. 1
    
2.
López-Briz E, Ruiz Garcia V, Cabello JB, Bort-Martí S, CarbonellSanchis R, Burls A. Heparin versus 0.9%sodium chloride locking for prevention of occlusion in central venous catheters in adults. Cochrane Database of Syst Rev 2018;7:CD008462.  Back to cited text no. 2
    
3.
News | The Royal Marsden NHS Foundation Trust [Internet]. Royalmarsden.nhs.uk; 2019. Available from: https://www.royalmarsden.nhs.uk/node/25/backlinks. [Last cited on 2019 Sep 11].  Back to cited text no. 3
    
4.
Schallom ME, Prentice D, Sona C, Micek ST, Skrupky LP. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: A randomized trial. Crit Care Med 2012;40:1820-6.  Back to cited text no. 4
    
5.
Bradford NK, Edwards RM, Chan RJ. Heparin versus 0.9% sodium chloride intermittent flushing for the prevention of occlusion in long term central venous catheters in infants and children: A systematic review. Int J Nurs Stud 2016;59:51-9.  Back to cited text no. 5
    
6.
Maintaining Patency of Central Venous Catheters in Adults: RMOC Position Statement [Internet]. SPS - Specialist Pharmacy Service; 2019. Available from: https://www.sps.nhs.uk/articles/maintaining-patency-of-central-venous-catheters-in-adults-rmoc-position-statement/. [Last cited on 2019 Sep 11].  Back to cited text no. 6
    
7.
Bigatello LM, George E. Hemodynamic monitoring. Minerva Anestesiol2002;68:219-25.  Back to cited text no. 7
    
8.
Vincent JL, Rhodes A, Perel A, Martin GS, Della Rocca G, Vallet B, et al. Clinical review: Update on hemodynamic monitoring--a consensus of 16. Crit Care2011;15:229.  Back to cited text no. 8
    
9.
McGee 2003 McGee DC, Gould MK. Preventing complications of central venous catheterization. New Engl J Med2003;348:1123-33.  Back to cited text no. 9
    
10.
Eisen LA, Narasimhan M, Berger JS, Mayo PH, Rosen MJ, Schneider RF. Mechanical complications of central venous catheters. J Intensive Care Med2006;21:40-6.  Back to cited text no. 10
    
11.
Chiang VW, Baskin MN. Uses and complications of central venous catheters inserted in a pediatric emergency department. PediatrEmerg Care2000;16:230-2.  Back to cited text no. 11
    
12.
Liangos O, Gul A, Madias NE, JaberBL. Long term management of the tunneled venous catheter. Semin Dial 2006;19:158-64.  Back to cited text no. 12
    
13.
Fuentes iPumarola C, CasademontMercader R, Colomer Plana M, Cordón Bueno C, SabenchCasellas S, Félez Vidal M, et al. Comparative study of maintenance of patency of triple lumen central venous catheter. EnfermIntensiva 2007;18:25-35.  Back to cited text no. 13
    
14.
Milani A, Mazzocco K, Gandini S, Pravettoni G, Libutti L, Zencovich C, et al. Incidence and Determinants of Port Occlusions in Cancer Outpatients [Internet]; 2019. Available from: https://www.ncbi.nlm.nih.gov/pubmed/26925994. [Last cited on 2019 Sep 11].  Back to cited text no. 14
    
15.
Verso M, Agnelli G. Venous thromboembolism associated with long-term use of central venous catheters in cancer patients. J Clin Oncol2003;21:3665-75.  Back to cited text no. 15
    
16.
Mermel LA. Prevention of intravascular catheter-related infections. Ann Intern Med2000;132:391-402.  Back to cited text no. 16
    
17.
Burns KE, McLaren A. A critical review of thromboembolic complications associated with central venous catheters. Can JAnaesth2008;55:532-41.  Back to cited text no. 17
    
18.
Sona C, Prentice D, Schallom L. National survey of central venous catheter flushing in the intensive care unit. Crit Care Nurse2012;32:e12-9.  Back to cited text no. 18
    
19.
Hadaway L. Technology of flushing vascular access devices. J InfusNurs2006;29:137-4.  Back to cited text no. 19
    
20.
Van Miert C, Hill R, Jones L. Interventions for restoring patency of occluded central venous catheter lumens (Review). Evid Based Child Health 2013;8:695-749.  Back to cited text no. 20
    
21.
Goossens GA. Flushing and locking of venous catheters: Available evidence and evidence deficit. Nurs Res Pract 2015;2015:985686.  Back to cited text no. 21
    
22.
Rabe C, Gramann T, Sons X, Berna M, González-Carmona MA, Klehr HU, et al. Keeping central venous lines open: A prospective comparison of heparin, vitamin C and sodium chloride sealing solutions in medical patients. Intensive Care Med 2002;28:1172-6.  Back to cited text no. 22
    
23.
Horne MK, McCloskey DJ, Calis K, Wesley R, Childs R, Kasten-Sportes C. Use of heparin versus lepirudin flushes to prevent withdrawal occlusion of central venous access devices. Pharmacotherapy 2006;26:1262-7.  Back to cited text no. 23
    
24.
Hemmelgarn BR, Moist LM, Lok CE, Tonelli M, Manns BJ, Holden RM, et al.; Prevention of Dialysis Catheter Lumen Occlusion with rt-PA versus Heparin (PreCLOT) Study Group. Prevention of dialysis catheter malfunctions with recombinant tissue plasminogen activator. New Eng J Med 2011;364:303-12.  Back to cited text no. 24
    
25.
Brito A, Nishinari K, Saad P, Saad K, Pereira M, Emídio S, et al. Comparison between Saline Solution Containing Heparin versus Saline Solution in the Lock of Totally Implantable Catheters [Internet]. 2019. Available from: https://www.cochranelibrary.com/cdsr/doi/10.1002/14651858.CD008462.pub3/references. [Last cited on 2019 Sep 11].  Back to cited text no. 25
    
26.
Society I. Infusion Nursing Standards of Practice. - PubMed - NCBI [Internet]. Ncbi.nlm.nih.gov. 2019. Available from: https://www.ncbi.nlm.nih.gov/pubmed/16429002. [Last cited on 2019 Sep 11].  Back to cited text no. 26
    
27.
Baglin T, Barrowcliffe TW, Cohen A, Greaves M; British Committee for standards in Hematology. Guidelines on the use and monitoring of heparin. Br J Haematol 2006;133;19-34.  Back to cited text no. 27
    
28.
Cancer Care Ontario Members of the Central Venous Access Device Guideline Panel | Course Hero [Internet]. Coursehero.com. 2019. Available from: https://www.coursehero.com/file/p7hatve/Cancer-Care-Ontario-Members-of-the-Central-Venous-Access-Device-Guideline-Panel/. [Last cited on 2019 Sep 11].  Back to cited text no. 28
    
29.
López-Briz E, Ruiz-Garcia V. Effectiveness of heparin versus NaCl 0.9% in central venous catheter flushing. A systematic review [Heparinafrente a clorurosódico 0.9% para mantenerpermeablesloscatéteresvenososcentrales. Una revisiónistemática]. Farm Hosp 2005;29:258-64.  Back to cited text no. 29
    
30.
Pratt RJ, Pellowe CM, Wilson JA, Loveday HP, Harper PJ, Jones SR, et al. epic2: National evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England. J Hosp Infect 2007;65(Suppl 1):S1-64.  Back to cited text no. 30
    
31.
Passannante A, Macik BG. The heparin flush syndrome: A cause of iatrogenic hemorrhage. Am J Med Sci 1988;296:71-3.  Back to cited text no. 31
    
32.
Garajová I, Nepoti G, Paragona M, Brandi G, Biasco G. Port-a-Cath-related complications in 252 patients with solid tissue tumours and the first report of heparin-induced delayed hypersensitivity after Port-a-Cath heparinisation. Eur J Cancer Care (Engl) 2013;22:125-32.  Back to cited text no. 32
    
33.
Dal Molin A, Allara E, Montani D, Milani S, Frassati C, Cossu S, et al. Flushing the Central Venous Catheter: Is Heparin Necessary? 2014 [Internet]. SAGE Journals; 2019. Available from: https://journals.sagepub.com/doi/10.5301/jva.5000225. [Last cited on 2019 Sep 11].  Back to cited text no. 33
    
34.
Da Ros L, Ponzo C, Storto S, Ciuffreda L. Assessment of randomised comparison of urokinase versus heparin. Eur J the use of heparinated solution for clamping medium/ Cancer 2001;37:2379-84.  Back to cited text no. 34
    
35.
Schallom ME, Prentice D, Sona C, Micek ST, Skrupky LP. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: A randomized trial. Crit Care Med 2012;40:1820-6.  Back to cited text no. 35
    
36.
Zhong L, Wang HL, Xu B, Yuan Y, Wang X, Zhang YY, et al. Normal saline versus heparin for patency of central venous catheters in adult patients-A systematic review and meta-analysis. Crit Care 2017;21:5.  Back to cited text no. 36
    
37.
You T, Jiang J, Chen J, Xu W, Xiang L, Jiao Y. Necessity of heparin for maintaining peripheral venous catheters: A systematic review and meta-analysis. Exp Ther Med 2017;14:1675-84.  Back to cited text no. 37
    
38.
Goossens GA, Jérôme M, Janssens C, Peetermans WE, Fieuws S, Moons P, et al. Comparing normal saline versus diluted heparin to lock non-valved totally implantable venous access devices in cancer patients: A randomised, non-inferiority, open trial. AnnOncol2013;24:1892-9.  Back to cited text no. 38
    
39.
Beigi AK, HadiZadeh MS, Salimi F, Ghaheri H. Heparin compared with normal saline to maintain patency of permanent double lumen hemodialysis catheters: A randomized controlled trial. Adv Biomed Res 2014;3:121.  Back to cited text no. 39
[PUBMED]  [Full text]  
40.
HeidariGorji MA, Rezaei F, Jafari H, Yazdani CJ. Comparison of the effects of heparin and 0.9% sodium chloride solutions in maintenance of patency of central venous catheters. Anesth Pain Med 2015;5:e22595.  Back to cited text no. 40
    
41.
Ziyaeifard M, Alizadehasl A, Aghdaii N, Sadehi A, Azarfarin R, Masoumi G, et al. Heparinized and saline solution in the maintenance of arterial and central venous catheters after cardiac surgery. Anesth Pain Med 2015;5:e28056.  Back to cited text no. 41
    
42.
Mahesh Babu BV, Kameswara Rao AS, Rajesh K, HarinathBabu V. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: A randomized trial. JEvolMed DentSci 2014;3:46-50.  Back to cited text no. 42
    
43.
Dal Molin A, Clerico M, Baccini M, Guerretta L, Sartorello B, Rasero L. Normal saline versus heparin solution to lock totally implanted venous access devices: Results from a multicenter randomized trial. Eur JOncolNurs 2015;19:638-43.  Back to cited text no. 43
    
44.
Klein J, Jepsen A, Patterson A, Reich RR, Mason TM. Flushing effectiveness in managing central venous catheters in patients undergoing blood and marrow transplantation. Clin JOncolNurs 2018;22:199-202.  Back to cited text no. 44
    
45.
Lyons MG, Phalen AG. A randomized controlled comparison of flushing protocols in home care patients with peripherally inserted central catheters. JInfusNurs 2014;37:270-81.  Back to cited text no. 45
    
46.
Santos E, Cunha M. Interpretaçãocrítica dos resultadosestatísticos de uma meta-análise: Estratégiasmetodológicas. Millenium 2013;44:85-98.  Back to cited text no. 46
    
47.
Dal Molin A, Allara E, Montani D, Milani S, Frassati C, Cossu S, et al. Flushing the central venous catheter: Isheparinnecessary? J Vasc Access 2014;15:241-8.  Back to cited text no. 47
    
48.
Randolph AG, Cook DJ, Gonzales CA, Andrew M. Benefit of heparin in central venous and pulmonary artery catheters: A meta-analysis of randomized controlled trials. Chest 1998;113:165-71.  Back to cited text no. 48
    
49.
Mitchell MD, Anderson BJ, Williams K, Umscheid CA. Heparin flushing and other interventions to maintain patency of central venous catheters: A systematic review. J Adv Nurs 2009;65:2007-21.  Back to cited text no. 49
    
50.
Bradford NK, Edwards RM, Chan RJ. Heparin versus 0.9% sodium chloride intermittent flushing for the prevention of occlusion in long term central venous catheters in infants and children. AVATAR Group: Making Vascular Access Complications History; 2019. Available from: https://www.avatargroup.org.au/our-publications.html. [Last cited on 2019 Sep 11].  Back to cited text no. 50
    
51.
Baskin JL, Reiss U, Wilimas JA, Metzger ML, Ribeiro RC, Pui CH, et al. Thrombolytic therapy for central venous catheter occlusion. Haematologica 2012;97:641-50.  Back to cited text no. 51
    
52.
Conway MA, McCollom C, Bannon C. Central venous catheter flushing recommendations: A systematic evidence-based practice review. J Pediatr Oncol Nurs 2014;31:185-90.  Back to cited text no. 52
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1]



 

Top
   
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   Abstract
  Introduction
   Materials and Me...
  Results
  Discussion
  Conclusion
  Medline search
  Embase search
   References
   Article Figures
   Article Tables

 Article Access Statistics
    Viewed962    
    Printed6    
    Emailed0    
    PDF Downloaded105    
    Comments [Add]    

Recommend this journal