Home Print this page Email this page Small font size Default font size Increase font size
Users Online: 20733
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 9  |  Issue : 7  |  Page : 3333-3337

Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status


Department of Conservative Dentistry and Endodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Chennai, India

Correspondence Address:
Dr. P Ajitha
Professor, Department of Conservative Dentistry and Endodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, 162, Poonamallee High Road, Chennai - 600 077, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jfmpc.jfmpc_73_20

Rights and Permissions

Aim: This study aims to assess the diagnostic accuracy of new custom-made pulse oximeter sensor holder in assessment of actual pulp status with three pulp sensibility tests. Materials and Methods: Seventy-nine single canal teeth requiring endodontic therapy was included in the study. The tooth that was requiring root canal treatment was tested with heat test, cold test, electric pulp test, and pulse oximeter. Between each test, a time period of 2 min was allowed. The response from three pulp sensibility tests and the reading from pulse oximeter were recorded. Following which root canal treatment was performed. The result obtained from four pulp tests were correlated with the clinical finding after access cavity preparation. The data obtained was statistically assessed. Receiver operator characteristic (ROC) curve analysis was performed to assess the efficacy of the pulp tests. In the above statistical tools, the probability value. 05 is considered as significant level. Results: The overall diagnostic accuracy was found to be significantly higher with pulse oximeter when compared with other three pulp sensibility tests. The ROC curve demonstrates the results obtained from pulse oximeter was found to be more reliable than other pulp tests. Conclusion: Within the limitation of the study, diagnostic accuracy of pulse oximeter with custom made sensor holder was reliable and accurate in assessment of actual pulp status.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed38    
    Printed0    
    Emailed0    
    PDF Downloaded10    
    Comments [Add]    

Recommend this journal